Intouch 10.1 Sp3 Patch 1

Last revision: About This Readme This Readme includes information about Wonderware System Platform 2014 Patch 01. The Patch 01 Readme updates the previous ReadMe file included with Wonderware System Platform 2014.

The entire Wonderware System Platform 2014 Readme is included in this document, following the Patch 01 sections. Wonderware System Platform 2014 Patch 01 Information Feature Enhancements Included in Wonderware System Platform 2014 Patch 01 This Patch release includes the following features and enhancements in addition to Resolved Issues.

All Wonderware System Platform 2014 Patch 01 Products Support for Microsoft Windows 8.1 and Windows Server 2012 R2 Operating Systems All products associated with the Wonderware System Platform 2014 Patch 01 include support for Microsoft Windows 8.1 and Windows Server 2012 R2 operating systems, with the exception of Wonderware Information Server:. Wonderware InTouch HMI 2014 Patch 01. (See for important information.). Wonderware Application Server 2014 Patch 01. Wonderware Historian 2014 Patch 01.

Wonderware Historian Client 2014 (version 10.5). Note: The server components of Wonderware Information Server 2014 (version 5.5) are not supported on Windows 8.1. Support for OPC UA Client Service Wonderware System Platform, in particular Wonderware Application Server and Wonderware InTouch HMI, now support OPC UA Client Service, installed optionally and separately from Wonderware System Platform 2014 Patch 01.

Wonderware Product Compatibility Updates Compatibility means that Wonderware products can communicate with each other over the network. Co-existence means that the products can be installed on the same computer. Wonderware System Platform 2014 Patch 01 includes the following product compatibility additions:. Wonderware InBatch™: Version 10.0 (2012 R2) SP1 is both compatible and co-existent. Wonderware InTouch HMI 2014 Patch 01 Programmatically Exporting and Importing ArchestrA Symbols InTouch HMI 2014 introduced a new application programming interface (API) to programmatically export or import a symbol between the ArchestrA Graphic Toolbox and an XML file.

In Patch 01, the programmatic API has been enhanced to include more symbol properties in export and import operations. Wonderware System Platform 2014 Readme Last revision: This document contains important information about Wonderware ® System Platform 2014, which includes:. Wonderware InTouch HMI 2014 (v11.0). Wonderware Application Server 2014 (v4.0).

Wonderware Historian Server 2014 (v11.5). Wonderware Historian Client 2014 (v10.5). Wonderware Information Server 2014 (v5.5) Use the following links to navigate this Readme file:.

You can find readme files for previous product releases at Log in to WDN with your username and password to access the downloads archive. About This Release Wonderware System Platform 2014 - General Notes Invensys License Manager Invensys License Manager provides a unified solution for enterprise management of Invensys product licenses, including functionality for importing, installing, and managing licenses on local machines, license servers, and remote machines. With Invensys License Manager, you can associate licenses with individual nodes on the system to assure correct software usage, install and manage licenses on local and remote notes, and check the validity of licenses on your system. Windows Operating Systems Wonderware System Platform 2014 component products support Windows 8 and Windows Server 2012 operating systems. The following Windows operating systems are no longer supported:. Windows XP, all versions. Windows Vista, all versions.

Windows Server 2003, all versions. Windows Server 2008, non-R2 versions Replacing SPC Pro with QI Analyst SPCPro ™ is a Statistical Process Control (SPC) utility formerly available with InTouch HMI. SPCPro is no longer supported by InTouch HMI. We recommend that if you use SPC and SPCPro with InTouch that you migrate your SPC Pro databases to the latest version of QI Analyst. QI Analyst provides support for the latest operating systems and DBMS versions, and provides a migration utility to move your SPCPro database to a QI Analyst database, leaving the existing SPC Pro database intact.

Please contact your local Wonderware sales representative for further information. Important Note: We strongly recommend that you migrate your current SPCPro databases to QI Analyst before installing Wonderware System Platform 2014 with InTouch HMI. InTouch 2014 no longer includes SPCPro, and will not open or migrate applications containing SPCPro components.

Wonderware InTouch HMI 2014 Situational Awareness Library InTouch HMI 2014 adds support for Situational Awareness Library symbols as part of the Base Galaxy.

Wonderware® InTouch 10.1 SP3 Patch 01 Readme Wonderware® InTouch® HMI Version 10.1 Service Pack 3 (SP3) Patch 01 Readme Last revision: About This Readme This document includes information about Wonderware®InTouch®HMI 10.1 SP3 (Service Pack 3) Patch 01. It updates the previous ReadMe files included with Wonderware InTouch HMI 10.1, Wonderware InTouch HMI 10.1 SP2, Wonderware InTouch HMI 10.1 SP2 Patch 01, and Wonderware InTouch HMI 10.1 SP3. Installation - You need to install InTouch 10.1 SP3 before installing this patch. If you have not installed InTouch 10.1 SP3, refer to the section below. Installation - Installing the InTouch HMI on a computer used as a domain controller is not supported. UAC - Disable UAC before installing the Wonderware Application Server 3.1 SP3 and InTouch 10.1 SP3, applicable for Windows Vista and newer operating systems.

Coexistence - If Wonderware Application Server and the InTouch HMI are installed on the same node, upgrade to Application Server 3.1 SP3 Patch 01 and InTouch 10.1 SP3 Patch 01, respectively. InTouch Memory Usage - The default value for InTouch internal shared memory management (WWHeap) has been changed to use more memory rather than the current default of 256 MB. In a 32-bit operating system, the default maximum memory of WWHeap is 1.5 GB. Special configuration can increase the maximum limit to nearly 2 GB. In a 32-bit environment, the InTouch memory management can be extended to 3 GB by adding the /3GB switch in the Boot.ini file.

An entry in the boot.ini file with the /3GB switch looks like the one given below: operating systems multi(0)disk(0)rdisk(0)partition(1) WINDOWS='Microsoft Windows XP Professional' /fastdetect /3GB If the /3GB switch is enabled in Windows, then the paging file size should be set to a system managed size, and InTouch can access up to 3 GB of memory. In a 64-bit operating system, it is not necessary to edit the Boot.ini file and InTouch can use up to 4 GB memory. For additional information, refer to Microsoft Knowledge Base articles, such as KB 328882. InTouch Window Caching - View.exe now supports hybrid functionality to keep some selected windows in memory, and load the rest from the disk. To enable this functionality, you must do the following:.

Intouch 10.1 Sp3 Patch 1

In WindowMaker, click Configure, then click WindowViewer, and clear the “Always load windows from disk” check box. In the InTouch.ini file, under the InTouch section, add a new entry “EnableCaching=1”. In the Application folder, create a file named “WindowCache.inf”.

Edit WindowCache.inf using Notepad or a similar text editor. In the WindowCache.inf file add a header labeled High Priority Windows. Under the header, add the window names that you want to keep in the memory while Windows is running using the =1 syntax.

An example of the WindowCache.inf file is given below: High Priority Windows OverViewWindow =1 TankFarm1 =1 AlarmBanner =1. Alarm DB Logger - The Alarm DB Logger has been enhanced to run as a Service in Windows Vista and later operating systems primarily to support Galaxy Alarms and InTouch Alarms from Terminal sessions.

Intouch 10.1 Sp3 Patch 1 Download

Intouch 10.1 sp3 patch 1 download

In prior releases that supported Vista, Windows 7, or Windows 2008, the Alarm DB Logger could not be enabled to run as a service. The issue has been corrected, with the following known limitation: The combination of Alarm DB Logger configured as a service and InTouch running locally as a console application is still not supported. If InTouch needs to run in the Console session, the Alarm DB Logger must be configured in the Alarm DB Logger Manager as a “Normal Application” instead of a “Windows Service”. Please refer to updated Tech Note 725, 'Running InTouch and AlarmDBLogger Services on Vista and Later Operating Systems,' for full details of the supported scenarios and applicable alarm query syntax. Galaxies with ArchestrA Symbols or InTouchViewApp Objects containing ArchestrA Symbols that leverage the Runtime Language Switching functionality must always be modified on the same language operating system and InTouch language version, on which it was initially developed. Attempts to modify these components in a different language operating system, or a different InTouch language version, may cause unexpected functional or operational issues that are not currently supported. Published applications running in an operating system language that is different from the originally developed language are supported.

Refer to Known Issues CRs L00088974, L00088993, and L00088998. Review the list. Windows Server 2008 R2 no longer supports the /console switch as a means of setting the Remote Desktop Client (RDC), also known as a console session. Click this link for further information about Terminal Services behavioral changes. If you are running WindowViewer within a Terminal Server session and want to access alarms from WindowViewer in a client session, you must use the syntax terminalservernode: InTouch!$System to access the alarms, with a colon (:) after the node name. Click this link for more information about Terminal Services behavioral changes.

Intouch 10.1 Sp3 Patch 1 2

Starting the ArchestrA Licensing Utility from an existing License CD may not work on a 64-bit operating system. Start the utility from the installed shortcut instead. All the restrictions applicable to Windows Vista and Windows Server 2008 are also applicable to Windows 7 and Windows Server 2008 R2, respectively. Wonderware InTouch HMI Version 10.1 SP3 Patch 01 Information Wonderware InTouch HMI Version 10.1 SP3 Information Wonderware InTouch® HMI Version 10.1 SP2 Patch 01 Information Wonderware InTouch® HMI Version 10.1 SP2 Information InTouch HMI Version 10.1 Information System Requirements The hardware and software requirements for this patch are the same as for the previous release.